Address : 13/F, Building 3, Tsinghua Science Park, 101 University Road,Zhuhai, Guangdong, China

Copyright: Zhuhai Longtime Biological Technology Co., Ltd 

鄂ICP备17014397号-1     Powered by www.300.cn

PRODUCTS

Cell Preparation Tube (CPT)

basic information
heat:
没有此类产品
产品描述
Product Description:
 
Collecting blood from the human body and isolating single nuclear cells is the first step in many in vitro experiments. The currently recognized method is the Ficoll Hypaque centrifuge method. When the number of samples is large, the method of gradually adding the anticoagulant Ficoll Hypaque to the centrifuge tube is time-consuming with high risk of cross contamination.
 
Mononuclear Cell Preparation Tube (CPT Tube) adds built-in Ficoll Hypaque, anticoagulant and separation gel design.  Can easily isolated lymphocytes and mononuclear cells from the whole blood separated by one-step centrifugation with specialized cells separation gel. Mainly used in lymphocyte immune function detection, HLA or residual leukemia gene detection and immune cell therapy, to provide one-step extraction of mononuclear cells standardized method for the preparation of clinical diagnostic specimens and cell immunotherapy.
 
LONGTIME Cell Preparation Tube (CPT) adds built-in Ficoll Hypaque, anticoagulant and separation gel, Can easily isolated Mononuclear from the whole blood separated by one-step centrifugation with specialized cells separation gel. 
 
LONGTIME CPT mainly used in lymphocyte immune function detection, HLA or residual leukemia gene detection and immune cell therapy, to provide one-step extraction of mononuclear cells standardized method for the preparation of clinical diagnostic specimens and cell immunotherapy.
 
Longtime
 
Product advantages:
 
One-step separating cells, can save time and simplify the process of isolating mononuclear cells in peripheral blood (centrifugation for 10 minutes), processing more samples in limited time to improve efficiency and output.
 
One-time use of vacuum collection and separation can be used as an in vitro diagnosis to minimize the experimental variation in the density gradient separation method.
 
One-step separation method and a closed vacuum blood collection system reduce the sample contamination and avoid the risk of exposure to dangerous blood (TB detection, HIV testing...).
 
The recovery rate of single mononuclear cell is above 90%, the purity is above 95%, and the survival rate is over 99%.
 
Technical advantages:
 
Cells precise separation technology
●The maximum recovery of mononuclear cells is high.
●It effectively removes NEUT, EO, BA, RBC, and the purity of mononuclear cells is high.
●Only need one step to isolate individual nuclear cells easy.
 
Inner wall bionic membrane processing technology
●Effectively protecting the activity of individual nuclear cells, high cell survival rate
●Blood samples can be temporarily stored in the tube (within 24h)
 
Performance Advantage
 
Longtime
 
Security guarantees
●The whole process is closed operation to eliminate pollution.
●It is sterile, pyrogen-free, no cytotoxicity, no sensitization, no skin reaction, no acute systemic toxicity, good blood compatibility.
●The CPT tubes  has been passed《Guangdong Medical Devices Quality Surveillance and Test Institute》Biological safety assessment.
 
Operation steps
①CPT Tube before blood collection
②CPT Tube after blood collection
③Reverse mixing 5-10 times
④1500g take out after 10min centrifugation
⑤The plasma 
  Mononuclear cell
  Separator gel
  Granulocyte
  Red blood cells
⑥Take out the monocyte layer for using in cell count and cell culture
On a
Platelet Rich Plasma Preparation Kit (PRP Tube)
The next article
Brucella coombs gel test card